Kromschroder BCU 580WC1F2U0D1K1-E, burner control unit (88670413)
Brand: Kromschroder
SKU:
88670413
Kromschroder
88670413
Kromschroder burner control unit
Housing for control cabinet installation, for controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. For continuous operation with ionization control or UV control using Kromschroder UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power module for fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft.
Version for pilot and main burners
EU certified, certified for systems up to SIL 3 (compliant with PL e)
Mains voltage: 230 V AC, 50/60 Hz
With valve proving system
Modulating capacity control with interface for RBW
Flammen?berwachung mit Ionisations- oder UV-Signal
High temperature operation
Screw connection terminals
Individual packaging
Flame control: burner 1: ionization, burner 2: UVS
01 Switch-off threshold, burner/pilot burner: 5 micro A
02 Main burner switch-off threshold: 5 micro A
06 High temperature operation: during intermittent operation with UVS
07 Burner/pilot burner start-up attempts: 2
08 Burner start-up attempts: 1
09 Restart: no
Safety time during operation: 2 s
40 Capacity control with RBW
41 Selection of running time: on; for approaching the positions for minimum/maximum capacity
42 Running time: 30 s
48 Air actuator can be activated externally
49 Air actuator can be activated externally on start-up
50 Air actuator can be activated in the event of malfunction
51 Valve proving system: tightness test before start-up
52 Relief valve (VPS): V3
56 Measurement time Vp: 10 s
59 Valve opening time V1 (tL1): 2 s
61 Minimum burner on time tB: 0 s
62 Minimum pause time tBP: 0 s
67 Operating time in Manual mode limited to 5 min.
68 Function of terminal 50:purge with High signal
69 Function of terminal 51: IC 40/RBW max. capacity feedback
77 User-defined password
78 Burner application: burner and pilot burner
79 Pilot burner: with shut-down
94 1st safety time on start-up: 5 s
95 Flame proving period 1 tFS1: 2 s
96 2nd safety time on start-up: 3 s
97 Flame proving period 2 tFS2: 0 s
80 Fieldbus communication: with address check
Housing for control cabinet installation, for controlling, igniting and monitoring impulse-controlled, modulating or stage-controlled gas burners. For continuous operation with ionization control or UV control using Kromschroder UV sensor UVD. Intermittent operation with UV sensor UVS. Long service life due to replaceable power module for fail-safe outputs. Display of the program status, unit parameters and flame signal. Manual operating mode. Diagnosis and adjustment of unit parameters via optical interface using PC software BCSoft.
Version for pilot and main burners
EU certified, certified for systems up to SIL 3 (compliant with PL e)
Mains voltage: 230 V AC, 50/60 Hz
With valve proving system
Modulating capacity control with interface for RBW
Flammen?berwachung mit Ionisations- oder UV-Signal
High temperature operation
Screw connection terminals
Individual packaging
Flame control: burner 1: ionization, burner 2: UVS
01 Switch-off threshold, burner/pilot burner: 5 micro A
02 Main burner switch-off threshold: 5 micro A
06 High temperature operation: during intermittent operation with UVS
07 Burner/pilot burner start-up attempts: 2
08 Burner start-up attempts: 1
09 Restart: no
Safety time during operation: 2 s
40 Capacity control with RBW
41 Selection of running time: on; for approaching the positions for minimum/maximum capacity
42 Running time: 30 s
48 Air actuator can be activated externally
49 Air actuator can be activated externally on start-up
50 Air actuator can be activated in the event of malfunction
51 Valve proving system: tightness test before start-up
52 Relief valve (VPS): V3
56 Measurement time Vp: 10 s
59 Valve opening time V1 (tL1): 2 s
61 Minimum burner on time tB: 0 s
62 Minimum pause time tBP: 0 s
67 Operating time in Manual mode limited to 5 min.
68 Function of terminal 50:purge with High signal
69 Function of terminal 51: IC 40/RBW max. capacity feedback
77 User-defined password
78 Burner application: burner and pilot burner
79 Pilot burner: with shut-down
94 1st safety time on start-up: 5 s
95 Flame proving period 1 tFS1: 2 s
96 2nd safety time on start-up: 3 s
97 Flame proving period 2 tFS2: 0 s
80 Fieldbus communication: with address check
Replacing a Kromschroder BCU 580WC1F2U0D1K1-E, 88670413 burner control unit is a good solution to make your equipment work again. We offer a wide range of Kromschroder spare parts for burners, gas trains etc. We supply original Elster (Kromschröder) & Honeywell (Maxon) products.
If you have any queries about Kromschroder burner control or any other Kromschroder spare parts, please write us at 624burner@gmail.com, quoting the item code 88670413.
- Running time 30 s
- Voltage 230 V AC
- Weight, kg 0,85
- Commodity code 90268020
- Country of origin DE