Honeywell C7061A1012/U UV flame detector 120V for R7861

Brand: Honeywell
SKU: C7061A1012/U
Quantity:
+
PRICE ON REQUEST
624burner@gmail.com
Shipping methods

TNT delivery service

Pick up in our office

Payment methods

Invoice payment

Cash

The Honeywell C7061A1012 flame detector is a dynamic self-monitoring flame detector designed to detect ultraviolet radiation generated during the combustion of gases, oil or other fuels.

The Resideo C7061A 1012 UV cell is designed for standard applications.

The flame detector is designed to be used in conjunction with an ultraviolet signal amplifier with dynamic self-monitoring type R7061 and a flame control relay R4348 or with an ultraviolet signal amplifier with dynamic self-monitoring type R7861A and 7800 series burner programmers. These configurations ensure the creation of a closed loop with a self-monitoring function, which guarantees the operability of both the amplifier and the detector. An incorrect response of the detector (false detection of flame failure) leads to an emergency stop and/or an alarm signal.

The terminal block on the Honeywell C7061A 1012/B flame detector is of the clamp type, with removable screws and is located in the compartment of the C7061A1012/U type detector. The ultraviolet radiation detection cell contains a radiation-sensitive tube, a shutter assembly, a terminal block and a magnifying lens. The UV radiation sensor can be mounted at a distance of up to 300 m from the flame control programmer/relay.

Features

- The oscillating shutter blocks the UV sensor 12 times per minute (when used with the R7861 amplifier and 7800 series programmer), providing a monitoring function. When combined with the amplifier R7061 and the flame control relay R4348, the gate oscillation frequency is 60 times per minute. The components of the amplifier circuit are monitored by a microprocessor in the 7800 series control unit.

- Detectors can be installed horizontally, vertically or at any angle. Models C7061 A 1012 with self-monitoring function require adjustment of the front panel. They have installation reference points that ensure the correct operation of the shutter mechanism.

- The UV sensor tube and quartz window can be replaced at the detector installation site.

- Two flame detectors can be connected in parallel to reduce the probability of false alarms in cases of difficult detection of the presence of a flame.

- To simplify the determination of the presence of a flame, the detector can be mounted on a swivel support.

- The tube of the UV radiation sensor is designed to operate at temperatures up to -40 °C (-40°F).

- The device has a built-in UV sensor monitoring function used with the R7061 and R7861 amplifiers with dynamic self-monitoring.

- A quartz viewing window for high pressure (50 lbs/sq.m.) can be installed as additional equipment. inch or 345 kPa), magnifying lens and vibration-isolating support.

- The housing complies with the IP67 protection standard.

- Built-in heat-resistant block in the mounting flange.

Technical specifications

- Model: UV flame detector with self-monitoring function in a standard case.

- Outdoor operating temperature range: -40°C to +70°C (-40°F to +160°F) (maximum outdoor temperature decreases by 1°F for every 13°F of aspirator temperature over 160°F).

- Storage temperature: -51°C to +85°C (-60°F to +185°C).

- Voltage and frequency: 120 V~, 50/60 Hz.

- Interchangeability: The model is not compatible with flame detectors of other models.

- Nominal pressure for quartz viewing window: maximum 138 kPa (20 lb/sq. inch).

- Weight: 3.3 kg (7.3 lb).

- Mounting and orientation: The mounting flange with an internal thread of NPT 3/4" is designed for mounting on the sighting pipe.

- Connection: Cable with multicolored cores, NEC Class 1. Length: 8 feet (2.4 m).

Spare parts and accessories

• 129464M UV detector tube.

• 129464N UV detector tube; for operation at temperatures up to -40°F (-40°C)

• 190971B Coil and shutter

• 114372 Quartz viewing window; nominal pressure 20 lbs/sq. inch (138 kPa).

• 114465 Gasket, silicone rubber; to install the viewing window (three pieces are required).

• 120739 Gasket, fiber-neoprene; for thermal insulation and sealing of the mounting flange.

• 118367A Rotary support

• 118369 Bushing, galvanized steel, with 3/4" NPT female thread at one end and 1" NPT male thread at the other end. To install a detector with an internal thread of NPT 1" on a sighting pipe with a 3/4" thread or on a pipe nipple and tee for connecting the air supply.

• 120934 Mounting flange (aluminum) with 3/4" NPT internal thread for mounting on the sighting pipe.

• 124198 Mounting flange (aluminum) with 1" NPT internal thread for mounting on the sighting pipe.

• 123539 Vibration-isolating support

• 124204 Quartz focusing lens, nominal pressure 20 lbs/sq. inch (138 kPa), to increase the sensitivity of the detector to ultraviolet radiation.

• 122748 Quartz viewing window; nominal pressure 50 lbs/sq. inch (345 kPa).

• 190105 Water jacket



Replacing a Honeywell C 7061 A 1012/U UV flame detector is a good solution to make your equipment work again. We offer a wide range of Honeywell spare parts for burners, gas trains etc. We supply original Elster (Kromschröder) & Honeywell (Maxon) products.

If you have any queries about Honeywell industrial flame detectors or any other Honeywell spare parts, please write us at 624burner@gmail.com, quoting the item code C7061A1012/U.

  • Commodity code 90275000
  • Country of origin MX
  • EAN code 085267148528